Skip to content

[bug] EV and Pixii charging anomalities #1975

Open

Description

@segran2

What happened?

EV and pixii charging works much better now after the last couple of weeks of beta updates, but still not entirely stable.

03:03–03:12 | The EV drew 0 W despite a request for 9.66 kW. Charging resumed at approximately 4.72 kW, limited by load balancing.

03:27–03:28 | FTW’s control loop stalled. The safety mechanism attempted to return the devices to autonomous operation; Pixii control was temporarily blocked and subsequently recovered.

04:18–05:12 | The EV showed no power response for approximately 54 minutes. At the start of the incident, Pixii was simultaneously charging at 6.95 kW, while the EV’s pilot current was 0 A.

05:45–05:55 | The EV drew 0 W despite a request for 10.35 kW. The warning cleared when the charging request changed to 0 W; this does not demonstrate that charging resumed.

N.B The 5:45 issue is no issue as the car was charged to 80%. The problem caused by FTW can't get fresh SoC from the car in real time.

Steps to reproduce

Run FTW according FTW plan.

Expected behavior

Charging to be balanced between Easee and Pixii within safe limits and without unexplained interruptions in Easee charging, 0W pilot a.s.o.

Version

v0.159.0-beta.1 + diagnostic patches to catch errors

Deployment

Native 0.x (install.sh)

Hardware / drivers in use

Pixii, Easee, SMA

Relevant logs

Anything else?

ftw-support-20261106-135957.zip

FTW-EV-Pixii-relevanta-incidenter-2026-11-06.zip

Activity

  1. segran2 commented on Nov 12, 2026

    @segran2
    ContributorAuthor

    Follow-up from the night of 12 November 2026 (CET, UTC+1) on FTW v0.163.0-beta.1 with local Easee pilot diagnostics.

    • 03:47–03:52: FTW requested 15 A per phase (10.35 kW), Easee signalled 13 A, and the car drew about 8.91 kW. FTW recorded a load-balancing limit at informational severity. Similar limits were recorded later in the session.
    • 03:26–03:28: Easee reported a 12 A dynamic setting with a 0 A pilot, 0 A allocated on all three phases and 0 W draw. Three resume calls were acknowledged. Pixii was near 0 kW during the retries and the highest measured grid phase was about 6.6 A. The detailed timeline is in #1948.
    • From 04:35: Measured EV power went to 0 W while Easee still reported a positive pilot of 7–12 A in several journal snapshots. FTW alternated between no power response and vehicle declined. The available measurements do not establish why the vehicle stopped drawing power.
    • Control loop: No matching stall or watchdog warning appeared in the FTW service journal for the checked window, 03:00–05:00. That observation is limited to this window.

    The positive-pilot stop remains open for investigation. The next occurrence would benefit from timestamped pilot mode, the Easee reason code, and fresh vehicle SoC where available.

    Sources: FTW control journal, Easee driver logs, Pixii phase-current and battery-power series, and FTW service journal.

  2. segran2 commented on Nov 13, 2026

    @segran2
    ContributorAuthor

    Follow-up from 13 November 2026 (CET) on the Easee installation:

    • 18:00: FTW requested 15 A and Easee acknowledged the resume commands. Easee reported a 6 A pilot and 6 A allocated per phase, while measured EV power stayed at 0 W throughout the two-minute trace. The owner suspects the car had reached its 80% charge limit. There is no contemporaneous SoC measurement in the trace to verify that.
    • 18:29: FTW requested 14 A. Easee again reported a 6 A pilot and 6 A allocated per phase. Measured power became positive after about 6.6 seconds and reached 4.17 kW. Startup traces
    • 18:39: A separate test on the exact Easee Cloud 1.5.0 candidate for device-drivers PR Map port 80 -> 8080 on RPi image + Documentation reshuffle (#199) #200 showed a 15 A request, 6 A pilot and 4.18 kW measured. The driver identified load balancing. Hardware validation

    These runs show that the car can start with the 6 A pilot on this installation. The cause of the earlier stop despite a positive pilot and the separate FTW control-loop stall remain open. The prolonged zero-pilot starts are tracked in #1948.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment